Rms-technologies 4-AXIS CONTROLLER/DRIVER Bedienungsanleitung Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
S I X P A C K / Q U A D P A C K 7
4 C O N N E C T O R A S S I G N M E N T
Motor Connectors: Attention: wrong pinning leads to damage to the pcb
never pull the connectors during operation!
Phase (coil) A of the motor is wired to connectors PHA1 and PHA2, Phase (coil) B to PHB1 and PHB2.
Electrical Reference Switch
The reference switch is connected to the pins „Ref_In“ and „GND“. Optionally a series resistance of
about 2.2kOhms can be inserted to match EMC demands. In general using an opener, i.e. a normally
closed switch is advisable. So broken cables can be detected. The reference input is equipped with a
Schmitt-trigger.
7PHA2
6PHB1
5PHB2
4GND
3 5V (15mA, 33 OHM)
2
Referenz In (22K Pullup,
TTL)
1 Analog In (0..5V)
8PHA1
PCB edge
Seitenansicht 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 32 33